The DP200H-003PH is suitable, for example, for load tests on high-voltage resistors, testing voltage dividers and investigating operating points in high-voltage assemblies. It offers a specified constant-voltage range of 600 V to 20 kV, an output current of 0 to 0,03 A and 600 W rated power. You can operate the instrument directly at the front panel or integrate it into automated test setups via the standard RS232 and RS485 interfaces with Modbus RTU or an optional LAN port.

Precision and output parameters
Digital CV/CC regulation stabilizes the output against mains and load changes. Voltage and current can be set and read with resolutions of 1 V and 0,01 mA respectively. In CC mode, the output voltage can fall to 0 V.
The output voltage is positive or negative with respect to earth, depending on the ordered configuration.
| Parameter | Voltage | Current |
|---|---|---|
| Setting and display resolution | 1 V | 0.01 mA |
| Setting and display accuracy | ≤0.2 % FS ± 2 LSB | ≤0.5 % FS ± 2 LSB |
| Ripple | ≤0.1 % FS | ≤0.1 % FS |
| Line regulation | ≤0.1 % + 2 LSB | ≤0.1 % + 2 LSB |
| Load regulation | ≤0.5 % + 2 LSB | ≤0.5 % + 2 LSB |
| Output Configuration | Positive or negative with respect to earth, according to the ordered configuration | |
Test procedures and interfaces
A test-system controller or computer can use the documented Modbus RTU protocol to set commands and read voltage/current measurements, CV/CC operating state and protection messages. Command response time is 50 ms.
The supplied Windows software lets you create voltage/current sequences, execute them on the connected power supply and record the resulting traces.
The optional LAN interface uses one of the two RJ45 ports assigned to RS485 in the standard configuration and can be configured as a server or client. On this model, the analog package replaces RS232. LAN and analog I/O can be ordered together.
| Interface | Configuration and signals |
|---|---|
| RS232 and RS485 | Standard equipment with Modbus RTU |
| LAN | Optional, configurable as server or client |
| Analogue I/O | Optional: U/I setpoints and both measured values. Common signal standard: 0V ... 5V, 0V ... 10V or 4mA ... 20mA. |

Output enable and protection
An interrupted 5 V interlock loop inhibits the output regardless of the control method. The function as an interlock or external ON/OFF trigger is selected when ordering and set at the factory.
The separate status output indicates normal operation with 5 V and a fault with 0 V. The equipment includes overtemperature, overvoltage and overcurrent protection, a short-circuit-proof output and passive protection against reverse currents of the same polarity. The front-panel controls can be locked.
2U enclosure and AC input
The standard DP200H-003PH operates from a single-phase 230 V mains supply. Rack brackets are included.
| DP200H-003PH | Enclosure and mains connection |
|---|---|
| Mains input, standard configuration | 207V ... 253V AC · 1 phase |
| Dimensions, standard configuration | 482,6 × 88 × 506 mm (W × H × D) · 2U |
| Weight, standard configuration | 14 kg |
| Mains frequency | 47Hz ... 63Hz |

Extensions for the test system
The AP5, AP7 and AP9 modules are made to order for additional load disconnection, mains-side filtering or protection against reverse current and reverse voltage.
| Module | Function |
|---|---|
| AP5 | Mechanical load isolation at the output. |
| AP7 | Additional three-stage mains-side EMI filter. |
| AP9 | Additional reverse-current and reverse-voltage protection using a protection circuit or active braking chopper. |
AP9 is sized for reverse current, reverse voltage, load energy and duty cycle. The electrical configuration and enclosure are specified with the order.
Similar models
The following DP-PH models offer the same maximum output voltage or the same rated power as the DP200H-003PH. The stated voltage ranges apply to CV operation. In CC operation, the output voltage can fall to 0 V if required.
Same output voltage: 20 kV
| Model | CV voltage range | Output Current | Rated power |
|---|---|---|---|
| DP200H-006PH | 600V ... 20kV | 0A ... 0.06A | 1.2 kW |
Same rated power: 600 W
| Model | CV voltage range | Output Current | Rated power |
|---|---|---|---|
| DP10H-06PH | 0kV ... 1kV | 0A ... 0.6A | 600 W |
| DP12H-05PH | 0kV ... 1.2kV | 0A ... 0.5A | 600 W |
| DP15H-04PH | 0kV ... 1.5kV | 0A ... 0.4A | 600 W |
| DP20H-03PH | 0kV ... 2kV | 0A ... 0.3A | 600 W |
| DP30H-02PH | 200V ... 3kV | 0A ... 0.2A | 600 W |
| DP40H-015PH | 250V ... 4kV | 0A ... 0.15A | 600 W |
| DP50H-012PH | 300V ... 5kV | 0A ... 0.12A | 600 W |
| DP60H-01PH | 500V ... 6kV | 0A ... 0.1A | 600 W |
| DP80H-0075PH | 500V ... 8kV | 0A ... 0.075A | 600 W |
| DP100H-006PH | 800V ... 10kV | 0A ... 0.06A | 600 W |
| DP120H-005PH | 1kV ... 12kV | 0A ... 0.05A | 600 W |
| DP150H-004PH | 450V ... 15kV | 0A ... 0.04A | 600 W |
| DP250H-0024PH | 750V ... 25kV | 0A ... 0.024A | 600 W |
| DP300H-002PH | 900V ... 30kV | 0A ... 0.02A | 600 W |