The DP30-120M is suitable, for example, for tests on DC input stages and industrial DC/DC power converters, and for load tests on resistor networks. With 0 to 30 V and 0 to 120 A, it delivers 3,6 kW rated power. You can set the output values at the front panel or integrate the power supply into automated test sequences via the standard RS232 and RS485 interfaces with Modbus RTU. Appropriately equipped units can also be integrated into existing DP-M parallel systems.

The DP-M series is being superseded by DP-P and DP-PH. Regular sales continue through 2027. After that, DP-M units remain available to existing customers for extending or supplementing their systems.
Precision and output parameters
Digital regulation switches automatically between constant-voltage and constant-current operation. Voltage and current are set and displayed with resolutions of 10 mV and 100 mA, respectively. PRESET allows a setpoint change to be prepared and applied only after confirmation.
In standalone operation, remote sensing on this 120 A model compensates for a lead voltage drop of up to 2 V. The output is floating and can be referenced to the test setup's potential.
| Parameter | Voltage | Current |
|---|---|---|
| Setting and display resolution | 10mV | 100mA |
| Setting and display accuracy | ≤(0,1% FS + 20mV) | ≤(0,3% FS + 50mA) |
| Line regulation | ≤0,2% FS | ≤0,2% FS |
| Load regulation | ≤0,2% FS | ≤0,2% FS |
| Ripple | ≤(0,3% FS + 50mV) RMS | ≤(0,3% FS + 10mA) RMS |
| Output Configuration | Floating | |
FS denotes the relevant full-scale value.
Models with an output voltage above 1500 V have a grounded output as standard.
Test procedures and interfaces
A test-stand controller, other controller or computer can use Modbus RTU to set values and query voltage and current measurements and unit status. This allows power stages to be tested at varying supply voltages and measurements to be recorded in your own test software. The optional LAN interface carries the serial commands over Ethernet.
A complete I/O package with external adapter is available for analog control in standalone operation. It includes voltage/current commands, both measured-value outputs and interlock loop A1. The same 0V ... 5V, 0V ... 10V or 4mA ... 20mA signal standard is selected for all four analog functions when ordering.
One interface is used at a time for remote control. Local operation is locked during remote control.
| Equipment | Function |
|---|---|
| RS232 and RS485, standard | Digital control and measurement queries using Modbus RTU |
| LAN, optional | Modbus RTU communication over Ethernet |
| Analog package, optional | Voltage/current commands and feedback, plus external output enable via A1, in standalone operation |

Protection and external enable
Adjustable overvoltage and overcurrent protection shut down the output when triggered. Overtemperature protection, fault indications and a short-circuit-proof output are also included. The front-panel controls can be locked. Active output discharge and integrated passive protection against reverse currents of the same polarity complement the output circuitry.
The interlock loop included in the optional analog package enables the output when closed and inhibits it when open.
19-inch rack mounting and mains connection
The DP30-120M occupies 2U in a 19-inch rack and is supplied with rack brackets. The enclosure measures 482 × 88 × 520 mm (W × H × D) and weighs 14,5 kg. It uses a single-phase 207V ... 253V AC supply at 47Hz ... 63Hz.
Extensions for the test system
The AP5 to AP9 modules are made to order for additional load disconnection, polarity reversal or filtering. Their electrical and mechanical configuration is matched to the supply and the connected load.
| Module | Function |
|---|---|
| AP5 | Mechanical isolation of the load from the output |
| AP6 | Output polarity switching locally or through an external control loop |
| AP7 | Additional three-stage mains-side EMI filter |
| AP8 | Three-stage EMI filter with additional load-side capacitance |
| AP9 | Application-specific reverse-current and reverse-voltage protection using a protection circuit or active braking chopper |
AP9 is sized for reverse current, reverse voltage, load energy and duty cycle. The enclosure and connections are specified with the order.
More power in a parallel master/slave system
With suitable parallel equipment, up to 99 compatible full-width DP-M modules with identical ratings can be connected as a master/slave system. The voltage range is retained, while the available total current increases with the number of modules. The master or slave role is set on the device.
The following examples each consist of six identical modules, one master and five slaves. Six DP3H-50M units provide, for example, 300 V, 300 A and 90 kW. The system is controlled at the master or digitally, using local voltage sensing. Analog control and remote sensing are unavailable in parallel operation.
| System voltage (max.) | Total current (max.) | System power (max.) | Power modules |
|---|---|---|---|
| 20 V | 3600 A | 72 kW | 6 × DP20-6HM |
| 30 V | 3000 A | 90 kW | 6 × DP30-5HM |
| 60 V | 1500 A | 90 kW | 6 × DP60-250M |
| 100 V | 900 A | 90 kW | 6 × DP1H-150M |
| 150 V | 600 A | 90 kW | 6 × DP150-1HM |
| 300 V | 300 A | 90 kW | 6 × DP3H-50M |
| 600 V | 150 A | 90 kW | 6 × DP6H-25M |
| 1000 V | 90 A | 90 kW | 6 × DP10H-15M |
| 1500 V | 60 A | 90 kW | 6 × DP15H-10M |
| 2000 V | 30 A | 60 kW | 6 × DP20H-5M |
The number of modules, mains distribution, output connections, cooling and protective circuitry are matched to the individual test setup.
Similar models
The following DP-M models offer the same maximum output voltage, the same maximum output current or the same rated power as the DP30-120M.
Same output voltage: 30 V
| Model | Voltage range | Output Current | Rated power |
|---|---|---|---|
| DP30-60M | 0 ... 30V | 0 ... 60A | 1.8 kW |
| DP30-2HM | 0 ... 30V | 0 ... 200A | 6 kW |
| DP30-250M | 0 ... 30V | 0 ... 250A | 7,5 kW |
| DP30-4HM | 0 ... 30V | 0 ... 400A | 12 kW |
| DP30-5HM | 0 ... 30V | 0 ... 500A | 15 kW |
Same output current: 120 A
| Model | Voltage range | Output Current | Rated power |
|---|---|---|---|
| DP1H-120M | 0 ... 100V | 0 ... 120A | 12 kW |