The DF-CC30V-2KA-40HZ-70HZ is suitable, for example, for temperature-rise tests on busbars, contact joints and windings, and for test systems requiring a defined AC current. Its single-phase output delivers up to 2 kA with a maximum open-circuit voltage of 30 V. Current and frequency can be adjusted locally, allowing test series at different current loadings without changing the source.
Constant current with a changing load
During temperature-rise tests, the resistance of conductors and contact joints changes as the test progresses. The current regulator adjusts the output voltage within the available voltage range to maintain the set AC current. This allows the current loading to be specified while the temperature rise of the test object is recorded.
The IGBT power stage uses PWM regulation to produce a sinusoidal output. Current stability is specified as ≤ ±0,5 % FS. The output is floating as standard and can be connected to PE when required. A configuration with a fixed earth reference can also be ordered to suit the test system.
| Parameter | DF-CC30V-2KA-40HZ-70HZ |
|---|---|
| Output | Single-phase AC |
| Maximum open-circuit voltage | 30 V |
| Maximum output current | 2.000 A |
| Rated power | 60 kVA |
| Output Frequency | 40-70 Hz |
| Current stability | ≤ ±0,5 % FS |
Test procedures and interfaces
The front panel combines current and frequency adjustment with output-value displays. Depending on the ordered configuration, RS232 or RS485 with Modbus RTU is available for integration into an automated test system. The test-system controller can then coordinate the current source with the measurement sequence.
The standard frequency range of 40 to 70 Hz covers tests around common mains frequencies. For other applications, configurations with frequency bands within 40 to 2,500 Hz are available to order. The required band is specified when the unit is configured.
Similar models
The following DF-CC models offer the same open-circuit voltage, maximum output current or rated apparent power. All listed standard configurations operate at 40-70 Hz.
Same open-circuit voltage: 30 V
| Model | Open-circuit U | Max. current | Rated power |
|---|---|---|---|
| DF-CC30V-1KA-40HZ-70HZ | 30 V | 1000 A | 30 kVA |
| DF-CC30V-3KA-40HZ-70HZ | 30 V | 3000 A | 90 kVA |
| DF-CC30V-5KA-40HZ-70HZ | 30 V | 5000 A | 150 kVA |
Same maximum current: 2 kA
| Model | Open-circuit U | Max. current | Rated power |
|---|---|---|---|
| DF-CC5V-2KA-40HZ-70HZ | 5 V | 2000 A | 10 kVA |
| DF-CC10V-2KA-40HZ-70HZ | 10 V | 2000 A | 20 kVA |
| DF-CC20V-2KA-40HZ-70HZ | 20 V | 2000 A | 40 kVA |
Same rated apparent power: 60 kVA
| Model | Open-circuit U | Max. current | Rated power |
|---|---|---|---|
| DF-CC20V-3KA-40HZ-70HZ | 20 V | 3000 A | 60 kVA |