DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 60 V, 0 … 20 A, 1.2 kW – DP60-20P-S
The DP60-20P-S delivers 0–60 V, 0–20 A, and 1.2 kW of rated power. This half-width model features digital CC/CV control, serial interfaces, and a standard interlock.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 60 V, 0 … 250 A, 15 kW – DP60-250P
The DP60-250P combines 0–60 V with 0–250 A and a rated power of 15 kW. CC/CV control and remote measurement up to 2 V support large DC loads in the low-voltage range.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This 15 kW model supports Master/slave parallel operation as standard and is available as a Master or slave version. AP5 through AP9 expand the features to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunctional Laboratory Power Supply 0 ... 60V 0 ... 25A 1.5kW - DP60-25P
The DP60-25P offers 0–60 V, 0–25 A, and 1.5 kW of rated power. Digital CC/CV control, serial remote control, and interlock support 24- and 48-V development setups.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunctional Laboratory Power Supply 0 ... 60V 0 ... 40A 2.4kW - DP60-40P
The DP60-40P delivers 0–60 V, 0–40 A, and 2.4 kW of rated power. Digital CC/CV control, serial interfaces, and a standard interlock complement the power reserve for 24-/48-V assemblies.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunctional Laboratory Power Supply 0 ... 60V 0 ... 50A 3kW - DP60-50P
The DP60-50P delivers 0–60 V, 0–50 A, and 3 kW of rated power. Digital CC/CV control, serial interfaces, and interlocks support the power supply for high-current DC assemblies.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunctional Laboratory Power Supply 0 ... 60V 0 ... 67A 4kW - DP60-67P
The DP60-67P offers 0–60 V, 0–67 A, and 4 kW of rated power. Digital CC/CV control, serial remote control, and interlock support high-current 24- and 48-V test setups.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunctional Laboratory Power Supply 0 ... 60V 0 ... 83A 5kW - DP60-83P
The DP60-83P delivers 0–60 V, 0–83 A, and 5 kW of rated power. Digital CC/CV control, serial interfaces, and a standard interlock complement the current reserve for DC power modules.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunctional Laboratory Power Supply 0 ... 6V 0 ... 200A 1.2kW - DP6-2HP
The DP6-2HP combines 0–6 V with 0–200 A at a rated power of 1.2 kW. CC/CV control, digital remote control , and a standard interlock round out this high-current DC power supply.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 800 V, 0 … 10 A, 8 kW – DP8H-10P
The DP8H-10P offers 0–800 V, 0–10 A, and 8 kW of rated power. Digital CC/CV control and serial remote control provide a wide DC voltage range for test benches.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 800 V, 0 … 12 A, 10 kW – DP8H-12P
The DP8H-12P offers 0–800 V and 0–12 A in the 10-kW power class. The digitally controlled output combines high DC voltage with a current range suitable for power modules.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 800 V, 0 … 18 A, 15 kW – DP8H-18P
The DP8H-18P combines 0–800 V with 0–18 A in the 15-kW power class. Digital CC/CV control and serial interfaces support high-voltage DC test stands.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This 15 kW model supports Master/slave parallel operation as standard and is available as a Master or slave version. AP5 through AP9 expand the features to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 80 V, 0 … 125 A, 10 kW – DP80-125P
The DP80-125P offers 0–80 V, 0–125 A, and 10 kW of rated power. The digital CC/CV control is supplemented by remote sensing up to 2 V and serial communication.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This model does not support Master/slave parallel operation; this feature is reserved for the 15 kW modules of the DP-P series. AP5 through AP9 expand the functionality to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Multifunction Laboratory Power Supply 0 … 80 V, 0 … 187 A, 15 kW – DP80-187P
The DP80-187P delivers 0–80 V and 0–187 A in the 15-kW power class. CC/CV control, remote measurement up to 2 V, and interlock complement the high-current output.
Comes standard with RS232 and RS485 for Modbus RTU and interlock. Optional LAN and a separately available analog I/O package round out the connectivity options. The analog package replaces RS232 and includes voltage and current setpoints as well as both actual value outputs. This 15 kW model supports Master/slave parallel operation as standard and is available as a Master or slave version. AP5 through AP9 expand the features to suit the application.
Both RJ45 communication ports are RS485 by default. With the LAN option, one RJ45 port becomes a LAN port; the other remains RS485. The remaining ports remain unchanged.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 120V 0 ... 7.5A 900W - DP120-7-5H
The DP120-7-5H offers 0–120 V and 0–7.5 A at a rated power of 900 W. CC/CV operation, user-defined test programs, and remote measurement are standard features.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 150V 0 ... 6A 900W - DP150-6H
The DP150-6H delivers 0–150 V, 0–6 A, and 900 W of rated power. Programmable test cycles and remote measurement complement the precise CC/CV control.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 15V 0 ... 60A 900W - DP15-60H
The DP15-60H delivers 0–15 V and 0–60 A at a rated power of 900 W. User-defined test programs, CC/CV control, and remote measurement support repeatable test sequences.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 20V 0 ... 45A 900W - DP20-45H
The DP20-45H combines 0–20 V, 0–45 A, and 900 W rated power. It offers programmable test sequences, constant-current and constant-voltage operation, and remote measurement.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 30V 0 ... 30A 900W - DP30-30H
The DP30-30H provides 0–30 V and 0–30 A at a rated power of 900 W. Its features include CC/CV control, user-defined test programs, and remote measurement.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 … 36 V, 0 … 25 A, 900 W – DP36-25H
The DP36-25H delivers 0–36 V and 0–25 A at a rated power of 900 W. User-defined test programs, remote measurement, and digital interfaces support its use in the test lab.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 … 45 V, 0 … 20 A, 900 W – DP45-20H
The DP45-20H provides 0–45 V, 0–20 A, and 900 W of rated power. Programmable test cycles, remote measurement, and CC/CV control facilitate its use in laboratories and on test benches.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 60V 0 ... 15A 900W - DP60-15H
The DP60-15H offers 0–60 V, 0–15 A, and 900 W of rated power. Programmable test sequences and remote measurement complement the digital CC/CV control.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
DC Laboratory Power Supplies (DC Voltage and Current Sources)
Precision Laboratory Power Supply 0 ... 80V 0 ... 11A 900W - DP80-11H
The DP80-11H combines 0–80 V and 0–11 A in the 900-W power class. Custom test programs, digital remote control, and remote measurement facilitate repeatable testing.
The device can store and automatically execute custom voltage, current, and power waveforms over time. A battery charging function complements the sequence programming. Comes standard with RS232/SCPI, RS485/Modbus RTU, analog 0 ... 5V I/O, and remote measurement up to 2V.
AC laboratory power supplies (AC voltage and AC current sources)
AC Industrial Power Supply 0 ... 300Vrms 0 ... 1.1kA 120kVA - DF-C61120
The DF-C61120 provides single-phase sinusoidal AC voltage ranging from 0 to 300 V RMS L-N at a rated apparent power of 120 kVA and a frequency of 47 to 63 Hz. The output is potential-free as standard.
Designed for continuous industrial operation with digitally controlled sinusoidal AC voltage. RS232, RS485, or analog I/O can be added as options to the front-panel controls. In addition to the variable range of 47 to 63 Hz, fixed frequencies of 100 Hz and 200 Hz are available upon request. The output is potential-free as standard.
AC laboratory power supplies (AC voltage and AC current sources)
AC Industrial Power Supply 0 ... 300Vrms 0 ... 1.26kA 450kVA - DF-C63450
The DF-C63450 provides three-phase 0–300 V RMS L-N, 450 kVA total rated apparent power, and 47–63 Hz. The sine-wave output is potential-free as standard.
Designed for continuous industrial operation with digitally controlled sinusoidal AC voltage. RS232, RS485, or analog I/O can be added as options to the front-panel controls. In addition to the variable range of 47 to 63 Hz, fixed frequencies of 100 Hz and 200 Hz are available upon request. The output is potential-free as standard.
AC laboratory power supplies (AC voltage and AC current sources)
AC Industrial Power Supply 0 ... 300Vrms 0 ... 1.36kA 150kVA - DF-C61150
The DF-C61150 provides single-phase 0–300 V RMS L-N, 150 kVA rated apparent power, and 47–63 Hz. Its sine-wave output is potential-free by default.
Designed for continuous industrial operation with digitally controlled sinusoidal AC voltage. RS232, RS485, or analog I/O can be added as options to the front-panel controls. In addition to the variable range of 47 to 63 Hz, fixed frequencies of 100 Hz and 200 Hz are available upon request. The output is potential-free as standard.




